热门关键词:

膜式燃气表计量稳定性的改善方法

  • 该文件为pdf格式
  • 文件大小:169.03KB
  • 浏览次数
  • 发布时间:2014-08-05
文件介绍:

本资料包含pdf文件1个,下载需要1积分

Value Engineering膜式燃气表计量稳定性的改善方法M ethods for Improving M etrological Stability of the Diaphragm Gas Meter杨红 日 YANG Hong-ri;张志云 ZHANG Zhi—yun;姜宏兵 JIANG Hong—bing;杨晓梅 YANG Xiao—mei(丹东东发集团股份 有限公 司,丹 东 l18003)(Dandong Dongfa(Group)Co.,Ltd.IDandong 118003,China)摘要:膜式燃气表的主要功能就是计量,而计量误差是否稳定可靠则是产品应用中的关键指标,通过分析膜式燃气表的计量原理及检测工艺,改善产品计量过程中的工作状态,以实现产品计量中示值误差的稳定可靠。

Abstract:The main function of diaphragm gas meter is metering,and the stability and reliability of the metering error is the keyindicator in the product application.By analyzing the metering principle and testing technique,the working state of product metering can beimproved SO that the indication error in product metering can be stable and reliable.

关键词:计量稳定性;示值误差;回转体积;钟罩检定法Key words:metrological stability;error of indication;cyclic volume;verification regulation of standard bel porver中图分类号:TH814 文献标识码:A 文章编号:1006—4311(2013)29—0311-021产品分析随着国内燃气事业的不断发展,膜式燃气表的计量稳定性 已成为燃气用户的关注重点。改善膜式燃气表的计量稳定性,提高计量准确度,则成为现今燃气表生产企业增强技术实力的有效手段。

膜式燃气表的检定包括示值误差、计量稳定性等关键性计量指标。根据 GB/T 6968—201 1《膜式燃气表》标准的要求,燃气表 的示值误差是用被测量燃气表的指示值与实际值之差同实际值的百分比来表示的,单次测量误差计算公式如 下 :E= x100% ? 式中 E一示值误差 :V广 被测燃气表的指示值 ;V 一被测燃气表的实际值。

判定燃气表的示值误差检定是否合格主要依据 GB/T6968—2011的标准规定,见表 1。

表 1流量 q/(m3/h、 初始最大允许误差q ≤q

目前国内燃气表产品的计量稳定性能存在差异化,如有的产品在同一流量点下的多次误差值产生较大波动,甚至超出了最大允许误差范围,这将给燃气用户在计量使用中造成诸多困扰。因此,就需要寻求措施来改善燃气表的计量稳定性 ,提高产品质量。笔者分析的改善方法如下,现与大家共同探讨。

2 计量稳定性能的改善方法作者简介 :杨红日(1980一),男 ,辽宁本溪人,主任工程师,中级工程 师,研究方向为仪器仪表。

影响计量稳定性的因素有多方面,其中主要因素有①计量检定的环境条件;②计量检定的方法要求;③燃气表传动机构的运转平稳性。而本文主要针对前两点,即燃气表的计量检定特性来进行技术探讨。

2.1计量检定的环境条件首先,从计量检定的环境条件来说,燃气表的检定方法通常有钟罩检定法、音速喷嘴检定法等。举例来说,若利用气体钟罩进行燃气表示值误差的检测时,其原理为钟罩内的气体通过管道阀门,再流经燃气表内部 ,以实现燃气表的运转计量功能。如图 l所示。

图 1在此检定过程中,大气压力、相对湿度、室温、钟罩内油温都是影响检定准确的关键要素。因为钟罩内的气体温度主要是受其内部的油温影响,燃气表的温度则受外部检定环境的影Ⅱ向。此时,应尽量保证钟罩内的油温与检测室温保持一致,以减小因温度差异化而导致的输出气体体积量发生变化,避免计量结果产生较大偏差。根据理想气体状态方程 PV厂I1的描述,可列 出定量气体从钟罩流经燃气表过程中的平衡状态公式: PcVc
:lC 1R式 中:P广 钟罩内气体压强 ;Vr 钟罩内气体体积量;Tr_钟罩内气体温度 ;P 燃气表进气口前端压强;V『_流经燃气表的气体体积量;· 312 ·矿井提升钢丝绳的选择计算Selection and Calculation of M ine Hoisting Rope王亭钧 WANG Ting-jun;谢贤平 XIE Xian—ping;叶巍巍 YE Wei—wei(昆明理 工大学国土资源I程学院,昆明 650093)(Land and Resources Engineering Faculty,Kunming University of Science&Technology,Kunming 650093,China摘要:为合理科学地选择矿井提升钢丝绳,从钢丝绳的安全系数、结构、捻向、使用环境等方面介绍了选绳时的参考因素。按钢丝绳在天轮(或导向轮)切点处所承受的最大静载荷,并考虑一定的安全系数,分别给出了立井单绳缠绕式、立井多绳摩擦式提升钢丝绳,以及斜井提升钢丝绳的选择计算公式及其推导过程。列举一实例,根据介绍了的选绳时的参考因素,用实际的矿井提升系统所对应的计算公式,对矿井提升钢丝绳进行了详细的计算、选型。

Abstract:In order to choose the mine hoisting rope reasonably,this article described the reference factors from the aspects of safetycoemeient,structure,twist,using—environment,ete.Considering the wire rope withstood the maximum static load at the tangent point of thesheave (or guide whee1)and certain safety coeficient,this article showed the formulas and derivation processes of the types of single—rope-winding and multi—rope-friction lifting system in shaft,as well as inclined shaft,and made an actual example of how to calculate and selectmine hoisting rope,using the corresponding formulas and referring to the introduced reference factors.

关键词:提升钢丝绳;立井;斜井;选择计算Key words:hoisting rope;shaft;inclined shaft;selection and calculation中图分类号:TD532 文献标识码:A 文章编号:1006—43l1(2013)29—0312—030 引言矿井提升钢丝绳是连接提升容器与提升机、升降人员与物料的具有传递动力功能的关键承载构件,对矿山企业的安全生产和正常运转起到至关重要的作用。选用钢丝绳时应考虑钢丝绳的结构、性能等因素,并应根据《煤矿安全规程》、《金属非金属矿山安全规程》(GB16423—2oo6)、《重要钢丝绳用途》fGB8918-2006)等标准规范 ,进行科学合理作者简介:王亭钧(1990一),女,江苏徐州人,在读硕士研究生,研究方向为矿山安全技术。

的选择。

1选择钢丝绳的参考因素1.1钢丝绳的安全系数 《煤矿安全规程》对不同用途钢丝绳悬挂时的安全系数规定如下:①对于单绳缠绕式提升装置,专为升降人员时≥9;升降人员和物料:升降人员时>--9,混合提升时>-9,升降物料时->7.5;专为升降物料时>-6.5。②对于摩擦轮式提升装置,专为升降人员时 9.2—0.0005H fH 为钢丝绳的悬垂长度);升降人员和物料:升降人员时>-9.2—0.0005H ,混合提升时 9.2—0.0005H ,升降物料时≥8.2—0.0005H ;专为升T 一检测环境温度。

由于压力恒定条件下,温度变化与体积变化成正比,因此会出现钟罩的排气体积量与流经燃气表的体积量差异明显 ,而随着恒温时间的加长,检定设备与检测环境温度之间的温度差将会逐渐缩小,直至相近甚至相 同的状态,而此时由于二者温差较小,其体积变化量也会变小,这就导致了初始状态和稳定状态下检测时,流经燃气表的气体体积量不同,进而使得多次检测所得到的示值误差值差异明显,影响计量稳定性能。

根据公式换算,通常钟罩内气体温度与燃气表的检测环境温度每相差 l℃,示值误差将变化约 0.34%。在实际生产中,为消除室温和油温存在差异化对燃气表计量所产生的影响,通常会将燃气表在检定环境下,恒温4h以上,待各项温度指标稳定后再进行检测。

2.2计量检定的方法要求根据JJG 577—2012(膜式燃气表》检定规程的推荐准则:示值误差的检定通气量应不少于燃气表最小分度值的200倍,而生产厂家或燃气公司在实际检定中,通气量也各不相同,有 20L、40L、60L、100L不等。而伴随着检定通气量的变化,燃气表的计量稳定性也将随之变化。

根据公式(1)可得 E=( 一1)xl00%,即使被测表指V示值 Vi在每次检测过程中略有不同,但作 为除数的 V(即实际检定体积量)数值越大,利用公式f1)计算出的多次示值误差就会相差越小,其计量稳定性也越好。反之,若检测过程中规定的实际检定体积越少,则检测同一台燃气表的计量稳定性也会越差。通常燃气表制造商在生产中均采用 40L~100L检定体积量,这也是综合生产效率及产品计量性能等因素,确定的较为理想的结果。

3 结束语影响燃气表计量稳定性的因素有很多,除本文所讨论的几点之外,诸如燃气表内部零部件的尺寸加工精度、传动机构的运转平稳性,燃气表内部滑阀系列的运转可靠性 ,都是保证燃气表计量稳定性能的重要因素,本文在这里就不加以详述。

参考文献:f11赫荣光.煤气表原理及检定【M1.北京:化学工业出版社,2003.

『21杨有涛.膜式燃气表『M1 E京:中国计量出版社,2006.

[3]张也影.流体力学[M】.北京:高等教育出版社,1999.

『412E洪欣,李木,刘秉忠.机械设计工程学『M1.徐州:中国矿业大学出版社 ,2001.