Analysis of Vibration Causes for W ax Oil Catalytic MachineGU Tongsheng(SINOPEC Guangzhou Branch,Guangzhou Guangdong 5 10700,China)Abstract:For the overhauled catalytic machine,abnormal phenomenon that vibration values on both sides of the bearing weredifferent with seven times was appeared at booting up.Vibration raised gradualy after the flue gas was put into the machine again。

Condition monitoring and fault diagnosis technology were used to diagnose the anomaly phenomenon. It is found that the cause of ab-normal vibration is big centering deviation between flue gas turbine and fan,and the reason of vibration rising after revamping flue gasis that rotor scaling. After confirming causes,a repair was immediately aranged,SO the abnormal vibration of the machine was trea-ted timely。

Keywords:Wax oil catalytic machine;Vibration某石化分公 司的蜡油催化装置烟机型号为 YL-12000A,进/排 气 温 度 670/490 oC,进/排 气 压 力0.35/0.108 MPa(ABS),输出功率11 750 kW ,工作转速5 813 r/min,机组的结构简图测点布置图如图1所示。

烟机 风机 减速箱 电机图 1 机组的结构简图测点布置图2012年5月 28日,经过大修的蜡油催化烟机开机,机组-启动,振动即出现异常现象--烟机叶轮侧 (XE1001/2)和联轴器侧 (XE1003/4)最大振动值竟然相差7倍多,其中叶轮侧最大值为8 txm,而联轴器侧最大值为62 m,该烟机报警值为 80 m。

另外当烟机投用烟气时状态和以前不同,以前投烟气后联轴器侧轴承的振动轻微下降,而这次反而上升,且随着烟气人口蝶阀开度逐渐打开 ,对应的烟机4个测点的振动都不断上升。针对烟机上述异常振动情况,采用状态监测和故障诊断技术,眷查找其异常振动原 因。

1 振动异常的测试分析过程1.1 两侧轴承振动相差大原因分析烟机组安装了 $8000实时在线状态监测故障诊断系统,分析烟机异常振动原因时就采用该系统。

烟机启动后 XEIO01、XE1002测点的振动值/间隙电压分别为8.0 In/-5.9 V、6.4 m/-6.5 V,XE1003、XE1004测点的振动值/间隙电压分别为56.4 H -6.4 V、62.1 H -6.4 V,烟机两侧振动值相差7倍之多,而4个振动探头的间隙电压都在正常范围之内。再看机组振动趋势,图2为开机后6天即5月 28日至 6月 3日间烟机前后轴承 4个振动测点的趋势图。从图 2来看 ,4个测点数据在变化趋势是同步的。依据4个测点间隙电压值及趋势图的变化趋势,可说明烟机两侧轴承振动值相差大并不是仪表信号干扰造成的,而是烟机出现了机械故障。 -烟机出现故障,对联轴器侧两个测点的振动信号再进行频谱分析,所得到的频谱图如图3所示。从图3来看,振动只出现了-个主要频率成分即工频。造成工频振动的原因有许多,如转子动不平衡、基础共振、角度不对中、轴承间隙过大或紧力不足等。

收稿日期:2013-01-30作者简介:古通生 (1964-),男 ,工程师,从事设备状态监测工作。E-mail:guts.gzsh###sinopec.corn。